| + | ====== Pediatric Cataract Surgery Suggested Residual Refraction ====== | ||
| + | ^ Age ^ Suggested Residual Refraction | ||
| + | | <1.9 months | ||
| + | | 2.0-3.9 months | ||
| + | | 4.0-5.9 months | ||
| + | | 6.0-11.9 months | ||
| + | | 1.0-1.9 years | +6 D | | ||
| + | | 2.0-3.9 years | +5 D | | ||
| + | | 4.0-4.9 years | +4 D | | ||
| + | | 5.0-5.9 years | +3 D | | ||
| + | | 6.0-6.9 years | +2 D | | ||
| + | | 7.0-7.9 years | +1.5 D | | ||
| + | | 8.0-9.9 years | +1 D | | ||
| + | | 10.0-13.9 years | +0.5 D | | ||
| + | | ≥ 14 years | Plano | | ||
| + | |||
| + | Source: M. Edward Wilson, Jr., MD, Medical University of South Carolina. | ||
| + | |||
| + | Other factors must also be taken into consideration before selection of the IOL power: fellow eye status, degree of amblyopia, assumed compliance and parental refractive error. | ||
| + | |||