Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| measuring_strabismus [2025/03/01 08:28] – Scott Larson | measuring_strabismus [2025/12/15 03:42] (current) – Scott Larson | ||
|---|---|---|---|
| Line 20: | Line 20: | ||
| * watch how their eyes look with distance and near targets | * watch how their eyes look with distance and near targets | ||
| * you should to be able to estimate the amount of manifest deviation with practice | * you should to be able to estimate the amount of manifest deviation with practice | ||
| - | * Corneal Refection tests | + | ===Corneal Refection tests=== |
| * Accommodation not controlled and fusion not suspended | * Accommodation not controlled and fusion not suspended | ||
| * **Hirschberg test** | * **Hirschberg test** | ||
| Line 31: | Line 31: | ||
| {{ :: | {{ :: | ||
| * Scleral Comparison | * Scleral Comparison | ||
| - | * compare the amount of white visible between the eyes | + | * compare the amount of white visible between the eyes |
| - | * **Prism Cover Tests** | + | * [[https:// |
| + | ===Prism Cover Tests=== | ||
| * Single Prism Cover Test | * Single Prism Cover Test | ||
| * Prism is placed over the deviated or paretic eye | * Prism is placed over the deviated or paretic eye | ||
| Line 68: | Line 69: | ||
| === Frontal Plane Position === | === Frontal Plane Position === | ||
| * **Horizontal and vertical prism bars** are calibrated for use in the frontal plane position. | * **Horizontal and vertical prism bars** are calibrated for use in the frontal plane position. | ||
| - | {{ :: | + | {{ :: |
| === Prism Stacking === | === Prism Stacking === | ||
| * Stacking two prisms in the same direction will induce measurement error | * Stacking two prisms in the same direction will induce measurement error | ||
| Line 89: | Line 90: | ||
| * This can cause diplopia and account for differences in measurements obtained in secondary and tertiary gaze positions. | * This can cause diplopia and account for differences in measurements obtained in secondary and tertiary gaze positions. | ||
| ===== References ===== | ===== References ===== | ||
| - | - {{:: | + | - [[https://1drv.ms/ |
| - [[https:// | - [[https:// | ||
| - | - {{:: | + | - [[https://1drv.ms/ |
| - | - {{:artifacts_introduced_by_spectacle_lenses_in_the_measurement_of_strabismic_deviations.pdf |Artifacts Introduced by Spectacle Lenses in the Measurement of Strabismic Deviations. Scattergood, | + | - [[https://1drv.ms/ |
| - | {{tag> | + | {{tag> |