Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| avastin_for_rop [2022/03/26 22:10] – Scott Larson | avastin_for_rop [2025/04/18 20:40] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 9: | Line 9: | ||
| * 30 unit Insulin syringe with 31 gauge/ 6mm needle | * 30 unit Insulin syringe with 31 gauge/ 6mm needle | ||
| * UIHC order set: | * UIHC order set: | ||
| - | * Currently (as of 3/ | + | * Currently (as of 3/26/2022) can be found under "NICU Bevacizumab (AVASTIN) for intravitreal injection" |
| * There will be 3 syringes ordered in case a problem occurs with one. | * There will be 3 syringes ordered in case a problem occurs with one. | ||
| * This order requires an overfill to 0.11 ml | * This order requires an overfill to 0.11 ml | ||
| Line 17: | Line 17: | ||
| * UIHC phone numbers | * UIHC phone numbers | ||
| * NICU Bay 1: 356-1671 | * NICU Bay 1: 356-1671 | ||
| - | * NICU Pharmacy Office: | + | |
| + | * NICU Bay 4: 384-9421 | ||
| + | * NICU level 6: 384-9000 | ||
| + | | ||
| * Children' | * Children' | ||
| Line 40: | Line 43: | ||
| - Grasp eye with toothed forceps to stabilize eye | - Grasp eye with toothed forceps to stabilize eye | ||
| - Hold syringe vertically and enter about 1 mm from limbus, aim posteriorly to avoid lens | - Hold syringe vertically and enter about 1 mm from limbus, aim posteriorly to avoid lens | ||
| - | - Slowly depress plunger and then when drug delivered, retract needle | + | - Slowly depress plunger and when drug delivered, retract needle |
| - Place new betadine soaked cotton tip applicator over injection site and hold pressure for a few seconds. | - Place new betadine soaked cotton tip applicator over injection site and hold pressure for a few seconds. | ||
| - | - Repeat steps 3-9 for fellow eye | ||
| === Syringe Delivery === | === Syringe Delivery === | ||
| Line 48: | Line 50: | ||
| - | {{tag> | + | {{tag> |