| ===== Dosing ===== | ===== Dosing ===== | ||
| * Lowest effective dose is not yet clear | * Lowest effective dose is not yet clear | ||
| - | * at UIHC using 25mg/ml concentration (undiluted) and giving 0.25 mg in 0.01 ml | + | * Current |
| + | * Avastin | ||
| ==== Ordering ==== | ==== Ordering ==== | ||
| - | * bevacizumab 25mg/ | + | * bevacizumab |
| * 30 unit Insulin syringe with 31 gauge/ 6mm needle | * 30 unit Insulin syringe with 31 gauge/ 6mm needle | ||
| + | * UIHC order set: | ||
| + | * Currently (as of 3/26/2022) can be found under "NICU Bevacizumab (AVASTIN) for intravitreal injection" | ||
| + | * There will be 3 syringes ordered in case a problem occurs with one. | ||
| + | * This order requires an overfill to 0.11 ml | ||
| + | {{:: | ||
| + | Med Order detail\\ | ||
| + | {{:: | ||
| + | * UIHC phone numbers | ||
| + | * NICU Bay 1: 356-1671 | ||
| + | * NICU Bay 2-3: 356-2888 | ||
| + | * NICU Bay 4: 384-9421 | ||
| + | * NICU level 6: 384-9000 | ||
| + | * NICU Pharmacy Office: 678-5286 | ||
| + | * Children' | ||
| - | ==== Syringe Delivery | + | ==== Procedure |
| + | * Coordinate with NICU staff for procedural sedation | ||
| + | * Nursing workflow for UIHC {{ :: | ||
| + | === Supplies === | ||
| + | * UIHC Eye Injection Pack | ||
| + | * Includes plastic cup, cotton-tipped applicators, | ||
| + | * Betadine 5% ampule | ||
| + | * Tetrcaine or proparacaine drops | ||
| + | * Lid specula (one per eye if desired) | ||
| + | * Toothed forceps (0.12, 0.3 or Bishop Harman, one per eye if desired) | ||
| + | * Sterile gloves | ||
| + | * Facemask | ||
| + | === Suggested Procedure Steps === | ||
| + | - Tetracaine drops in both eyes | ||
| + | - Wipe around eyes and face with 4x4 gauze soaked in betadine | ||
| + | - Inspect syringe ensure plunger in proper location to deliver 0.01 ml (waste overfill) | ||
| + | - Place lid speculum | ||
| + | - Place drops of betadine in eye especially in area for injection with soaked cotton tip applicator | ||
| + | - Grasp eye with toothed forceps to stabilize eye | ||
| + | - Hold syringe vertically and enter about 1 mm from limbus, aim posteriorly to avoid lens | ||
| + | - Slowly depress plunger and when drug delivered, retract needle | ||
| + | - Place new betadine soaked cotton tip applicator over injection site and hold pressure for a few seconds. | ||
| + | === Syringe Delivery === | ||
| + | {{: | ||
| - | {{tag> | + | |
| + | {{tag> | ||